| Sequence
Voltage Regulators QBAR® switch
holds regulator down until sequencing logic HI is
received. Could be used, for example, to manage turn-on
and turn-off transients of main system supply.
|
 |
| Limit
Current for External PNP/PMOS Current
limiting (or other inhibit features) are provided for op
amps and other driver ICs which lack an inhibit pin. QBAR®
switch breaks the ICs ground lead when Iload is
excessive.
|
 |
| QB312 Off-Line Alarm A
QBAR® switch activates an alarm over a large
range of system failure conditions:
- system failure indicated by a LO on the status
output
- status conductor cut
- status conductor shorted to ground
- loss of +5 V supply
Any of these conditions will cause the QBAR®
switch to turn ON, powering the alarm.
|
 |
| Attenuator/Range
Switch Protects Amplifiers or Other Sensitive Devices A
QBAR® range switch attenuator protects
sensitive amplifiers from overdrive damage when the power
supply is interrupted or lost. QB312 types are well
suited to linear attenuator applications.
|
 |
| Booster
for LED Driver LED (and other
similar) drivers with low voltage and/or current
capability can drive high brightness displays and other
loads simply through non-inverting QBAR®
switches.
|
 |
| Drive
Push-Pull Loads Simply Push-pull
loads can be controlled by one signal wire, and without a
local logic supply. This Bottom Half H-Bridge provides
low-cost remote activation for brushless d.c. motors and
other phase/antiphase loads.
|
 |
| Simplify
Interfacing QBAR®
switches simplify interfacing when system outputs require
a non-inverting driver. Easy-to-drive QBAR®
switches require much less input/control current than
electromechanical or opto-electronic (solid-state) relay
coils or inputs. QBAR® switches also usually
operate much faster.
|
 |
| Schmitt
Inverter has Large Input Hysteresis on Low Supplies Inverter
(that's right!) provides large and controllable
hysteresis.
|
 |